Industrial Networking

CANopen Gateway from HMS Industrial Networks

Click for larger image
HMS Industrial Networks Inc.
April 10, 2011

The Anybus X-gateway CANopen from HMS Industrial Networks Inc., Chicago, IL, lets you transfer I/O data between automation devices on EtherNet/IP and CANopen. The configurable, stand-alone gateway mounts to a standard DIN rail. Powered by a 24 V supply the gateway acts as a slave on the EtherNet/IP network and as a master on the CANopen side. CANopen master functionality is configured using a software tool; after the initial configuration has been downloaded to the gateway, the device can pass up to 510 bytes of input and 510 bytes of output data transparently between EtherNet/IP and CANopen. Up to 126 CANopen slaves can be connected to the gateway using up to 128 receive PDOs and 128 transmit PDOs.


CompanyHMS Industrial Networks Inc.
CountryUnited States (USA)




Twitter Feed

Find It Fix It Forum

Sensors invites you to join the Findit-Fixit Forum, where you can get answers to your sensing questions—concerning technologies, products, methods, applications, and services--and also offer help to your fellow engineers. The Forum covers all kinds of topics, from the basics to the extraordinary.

Join the discussion!

© Copyright 2016 Questex, LLC. All Rights Reserved. Sensorsmag. Privacy Policy | Terms of Use